Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
J Clin Microbiol ; 59(7): e0083721, 2021 06 18.
Article in English | MEDLINE | ID: covidwho-1486488

ABSTRACT

We assessed the performance of the CoronaCHEK lateral flow assay on samples from Uganda and Baltimore to determine the impact of geographic origin on assay performance. Plasma samples from severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) PCR-positive individuals (Uganda, 78 samples from 78 individuals, and Baltimore, 266 samples from 38 individuals) and from prepandemic individuals (Uganda, 1,077, and Baltimore, 532) were evaluated. Prevalence ratios (PR) were calculated to identify factors associated with a false-positive test. After the first positive PCR in Ugandan samples, the sensitivity was 45% (95% confidence interval [CI], 24,68) at 0 to 7 days, 79% (95% CI, 64 to 91) at 8 to 14 days, and 76% (95% CI, 50 to 93) at >15 days. In samples from Baltimore, sensitivity was 39% (95% CI, 30 to 49) at 0 to 7 days, 86% (95% CI, 79 to 92) at 8 to 14 days, and 100% (95% CI, 89 to 100) at 15 days after positive PCR. The specificity of 96.5% (95% CI, 97.5 to 95.2) in Ugandan samples was significantly lower than that in samples from Baltimore, 99.3% (95% CI, 98.1 to 99.8; P < 0.01). In Ugandan samples, individuals with a false-positive result were more likely to be male (PR, 2.04; 95% CI, 1.03,3.69) or individuals who had had a fever more than a month prior to sample acquisition (PR, 2.87; 95% CI, 1.12 to 7.35). Sensitivity of the CoronaCHEK was similar in samples from Uganda and Baltimore. The specificity was significantly lower in Ugandan samples than in Baltimore samples. False-positive results in Ugandan samples appear to correlate with a recent history of a febrile illness, potentially indicative of a cross-reactive immune response in individuals from East Africa.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , Female , Humans , Male , Sensitivity and Specificity , Uganda
2.
J Clin Med ; 10(9)2021 Apr 21.
Article in English | MEDLINE | ID: covidwho-1201827

ABSTRACT

BACKGROUND: There is much data available concerning the initiation of the immune response after SARS-CoV-2 infection, but long-term data are scarce. METHODS: We thus longitudinally evaluated and compared the total and neutralizing immune response of 61 patients to SARS-CoV-2 infection up to eight months after diagnosis by RT-PCR using several commercial assays. RESULTS: Among the 208 samples tested, the percentage of seropositivity was comparable between assays up to four months after diagnosis and then tended to be more heterogeneous between assays (p < 0.05). The percentage of patients with a neutralizing titer decreased from 82% before two months postdiagnosis to 57% after six months. This decrease appeared to be more marked for patients under 65 years old and those not requiring hospitalization. The percentage of serology reversion at 6 months was from 11% with the WANTAI total assay to over 39% with the ABBOTT IgG assay. The neutralizing antibody titers decreased in parallel with the decrease of total antibody titers, with important heterogeneity between assays. CONCLUSIONS: In conclusion, serological tests show equivalent sensitivity in the first months after the diagnosis of SARS-CoV-2 infection, but their performance later, postinfection, must be considered when interpreting the results.

SELECTION OF CITATIONS
SEARCH DETAIL